air-conditioner error code
Timer indicator on LED display |
Error code on digital display |
Trouble source |
Priority class |
Flash 4 times per 8s |
E4 |
PG motor of indoor unit |
1 |
Flash 1 time per 8s |
E1 |
Temperature sensor of air intake |
2 |
Flash 2 times per 8s |
E3 |
Temperature sensor of indoor unit coil |
3 |
Flash 1 time per 1s |
E2 |
Temperature sensor of outdoor unit coil |
4 |
E5 |
Communication error between outdoor and indoor |
5 |
Q: What to do after getting these error codes:
A:
E1 (plastic sensor) /E3 (copper sensor)
- test resistance value (std: 5k? at 25�C) of sensor � if abnormal, replace with new one
- check cable connection with PCB
E2
- Signal cable between indoor and outdoor not connected due to unprofessionalism
- Outdoor copper sensor broken, resistance infinite � check cable, socket and sensor.
E4
- Check wire connection of indoor motor then restart appliance
- If E4 still display, replace PCB.
- Lastly, check the PG motor of indoor unit.
E5
- Outdoor
Inverter units
Errors for indoor unit
Error on digital display |
Timer indicator on LED display |
Trouble source |
E1 |
Flash 1 time in 8s |
Indoor room temp sensor |
E3 |
Flash 2 times in 8s |
Indoor coil temp sensor |
E4 |
Flash 6 times in 8s |
Indoor fan motor feedback |
E5 |
Flash 5 times in 8s |
Indoor and outdoor communication |
E6 |
Indoor E1PROM |
|
E7 |
100Hz overzero detect failure |
Error for outdoor units
Error on display |
Trouble source |
F0 |
Temp sensor of compressor or overheat switch protection |
F1 |
Outdoor temp sensor |
F2 |
Discharge temp sensor |
F3 |
Outdoor coil temp sensor |
F4 |
Overheat protection/discharge temp |
F5 |
Outdoor E2PROM |
F6 |
Module IPM |
F7 |
Protection of bus current |
F8 |
Module PFC |
Q: What happens when certain LED lights are on?
LED |
causes |
Error on control board |
1 |
Outdoor Temp sensor failure |
001 |
2 |
Outdoor coil temp sensor |
002 |
1,2 |
Compressor discharge temp sensor |
003 |
3 |
General back temp sensor |
009 |
1,3 |
Outdoor A back temp sensor |
010 |
2,3 |
Outdoor B back temp sensor |
011 |
1,2,3 |
Over/under voltage |
006 |
4 |
Over current |
005 |
1,4 |
Module abnormal |
004 |
2,4 |
Compressor overheat |
007 |
1,2,4 |
EEPROM abnormal |
008 |
|
Refrigerant leak |
012 |
|
Four-way valve switch |
013 |
|
Compressor discharge overheat |
014 |
|
Current mutual induction |
015 |
Q: What happens when certain LED lights are flashing?
1 |
Outdoor A overcooling/heating |
2 |
Outdoor B overcooling/heating |
1,2 |
Current protection |
3 |
Discharge protection |
1,3 |
Voltage protection |
2,3 |
Refrigeration overload |
Cassettes, under ceilings, ducts
Q: What do the error indications mean?
A:
Indication lamp on display |
Failure lamp on control board |
Error code on controller |
Phenomenon |
Cause |
Priority |
Flash 5 times in 2s |
Flash 2 times in 2s |
F1 |
Shutdown |
Communication |
1 |
- |
- |
E5 |
Shutdown |
Wired controller communication |
1 |
Flash 4 times in 2s |
E4 |
Shutdown |
Drainage system |
3 |
|
Flash 6 times in 2s |
E6 |
Shutdown |
Outdoor protection (Phase failure) |
2 |
|
Flash 10 times in 2s |
Flash 10 times in 2s |
EA |
Shutdown |
Outdoor protection (discharging over-temperature) |
7 |
Flash 9 times in 2s |
Flash 1 time in 2s |
E9 |
Shutdown |
High pressure protection |
6 |
Flash 9 times in 2s |
Flash 3 times in 2s |
E9 |
Shutdown |
Low pressure protection |
6 |
Flash 1 time in 2s |
E1 |
Shutdown |
Indoor temp sensor |
4 |
|
Flash 3 times in 2s |
E3 |
Shutdown |
Indoor coil sensor |
5 |
|
Flash 2 times in 2s |
Flash 2 times in 2s |
E2 |
Non-stop |
Outdoor coil sensor |
8 |
Flash 7 times in 2s |
Flash 7 times in 2s |
E7 |
Non-stop |
Outdoor condensate temp sensor |
9 |
Flash 8 times in 2s |
Flash 8 times in 2s |
E8 |
Non-stop |
Discharging temp sensor |
10 |